Prediction of acute cardiac rejection by changes in left ventricular volumes

Academic Article

Abstract

  • Sixteen patients underwent heart transplantation (11 orthotopic, five heterotopic). Monitoring for acute rejection was by both endomyocardial biopsy (EMB) and multigated equilibrium blood pool scanning with technetium 99m-labelled red blood cells. From the scans information was obtained on left ventricular volumes (stroke, end-diastolic, and end-systolic), ejection fraction, and heart rate. Studies (208) were made in the 16 patients. There was a highly significant correlation between the reduction in stroke volume and end-diastolic volume (and a less significant correlation in end-systolic volume) and increasing acute rejection seen on EMB. Heart rate and ejection fraction did not correlate with the development of acute rejection. Correlation of a combination of changes in stroke volume and end-diastolic volume with EMB showed a sensitivity of 85% and a specificity of 96%. Radionuclide scanning is therefore a useful noninvasive tool for monitoring acute rejection.
  • Authors

    Author List

  • Novitzky D; Cooper DKC; Boniaszczuk J
  • Start Page

  • 453
  • End Page

  • 455
  • Volume

  • 7
  • Issue

  • 6