High strain rate effects in infrastructure composites with polycarbonate facing

Academic Article

Abstract

  • Impact damage is of critical concern structures using laminated fiber reinforced composites. In the current study, high strain rate impact testing was carried out on panels of both S-2 glass/epoxy and graphite/epoxy laminate systems "with" and "without" polycarbonate (PC) facing. The results of the investigation showed that providing a PC facing is an effective way of obtaining deformation in the facing to absorb a large portion of the incident energy, thereby minimizing any delamination threat to the composite laminate. The PC acts as a sacrificial layer that can be readily replaced in the application.