Estimation of extracellular fluid volume from plasma clearance on technetium-99m DTPA by a single-injection, two-sample method.

Academic Article

Abstract

  • A simple method is presented for estimating extracellular fluid volume from the plasma clearance of [99mTc])DTPA or [169Yb]DTPA. Two plasma samples are required, at 1 and 3 hr, following a single intravenous injection. (The same plasma samples can be used for measurement of glomerular filtration rate.) Using the complete plasma clearance curve as a reference (eight samples at 10 to 240 min), the error of the two-sample method in 40 patients was 1.5 I for [99mTc]DTPA, 2.1 I for [169Yb]DTPA (residual standard deviation).
  • Published In

    Keywords

  • Extracellular Space, Humans, Kidney Function Tests, Organometallic Compounds, Pentetic Acid, Technetium, Technetium Tc 99m Pentetate
  • Author List

  • Russell CD; Bischoff PG; Rowell KL; Lloyd LK; Dubovsky EV
  • Start Page

  • 255
  • End Page

  • 258
  • Volume

  • 29
  • Issue

  • 2